Understanding The Application Of Daniel Orifice Plate

The sizing of Daniel orifice plate is normally done with software provided by manufacturers of the device. The orifice plate meter provides a restriction to the flow and create the necessary differential pressure. Well, it is one of the most popular and versatile flowmeter on the market.

The sizing of Daniel orifice plate holder consists of three elements – a primary element to create the DP signal, a transmitter to measure the DP and convert it to the electronic and digital signal. The tertiary elements calculate the displays, stores and transmits the corrected flow rate on the basis of measured values.

Choosing The Right Specification

Any successful orifice meter deployment is based on establishing the right specification and ensure that the orifice plate meter is sized correctly. For custody transfer application it is required to have a list of specifications.

Variables like liquid and gas amounts also need to be considered with orifice meter accuracy maintained in liquid stream to contain up to 5.5 percent by volume of gas and up to 2.2 percent by weight of liquids in gas.

Choose The Right Orifice Holding Tool

Another crucial question at the outset would be choice of orifice holding device. Proper fitting is very crucial for the accuracy and performance as it required for flexibility while removing and replacing plates.

Dual chamber orifice fitting is another option that allows the removal of the plate under flowing conditions. The dual chamber is separated by a slide valve with a gear shaft. Once the slide valve is closed and the pressure is bled from the top chamber – the orifice plate can be removed safely.

In addition, there are multi-hole orifice plate to combine the technologies of orifice plate and flow conditioner for making a measurement device with short upstream piping installation requirements. Such device comes with traditional single-hole orifice plate deign however have several bores to distribute the flow through smaller bores rather the single large bore.

The Importance of Maintenance

Frequent inspection and maintenance of the meter should be conducted for reducing lost and unaccounted for corresponding liquid. Monthly operation of the fitting is also recommended that includes opening, closing and lubricating the slide valve for rotating the gear shafts and cleaning the drain plug holes. These steps should be performed once the senior fitting has been depressurized and the line has been blown down.

Comments

Popular posts from this blog

Everything You Should Know About Turbine Flow Meter

Accurate Liquid Turbine Flow Meters for Oil and Gas Applications

How Can Excel Loading System Help You